High Voltage Protection Busbar Heat Shrink Tube

Product Details
Customization: Available
Application: Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell, Motor, Insulating Varnish, Switch Baseplate, Busbar etc
Color: Rust Red and Others
Still deciding? Get samples of US$ 0/Meter
Request Sample

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, IATF16949
Export Year
2008-04-01
  • High Voltage Protection Busbar Heat Shrink Tube
  • High Voltage Protection Busbar Heat Shrink Tube
  • High Voltage Protection Busbar Heat Shrink Tube
  • High Voltage Protection Busbar Heat Shrink Tube
  • High Voltage Protection Busbar Heat Shrink Tube
  • High Voltage Protection Busbar Heat Shrink Tube
Find Similar Products

Basic Info.

Model NO.
SB-WMPG SERIES
Material
Polyolefin
Maximum Voltage
>100KV
Thermal Rating
125c
Working Temp
-55~+125 C
Shrink Temp
84~125c
Shrink Ratio
2:1 & 2.5:1
Standard Color
Red, Black, Blue, Green, Yellow etc
Voltage
1kv, 10kv, 35kv
Type
Insulation Sleeve & Tube
Chemistry
Organic Insulation
Classification
Organic Insulating Material
Certification
ISO9001, Ts16949
Brand
Sunbow
Transport Package
Carton Package or Pallet Package
Specification
ID15~250MM
Trademark
SUNBOW
Origin
Shenzhen, China
HS Code
3917310000

Product Description

High Voltage protection Busbar Heat Shrink Tube
Model Number: SB-WMPG SERIES

Working temperature: -55ºC ~ 125ºC  
Shrink temperature: 84ºC ~ 125ºC 
Shrink ratio: 2:1(1KV, 35KV), 2.5:1(10KV)
Environmental, flexible, flame retardant, sof

Structure
Bus-bar heat shrinkable protection tube adopts cross-linked and environmental friendly polyolefin material. It restricts the hazardous substance in PBB, PBBD, PBBE and other heavy metal, and supplies high dielectric strength and voltage withstand performance. It prevents bus-bar from chemical corrosion effected by strong acid, alkali, salt etc. It also has environmental friendly, flexible, flame retardant, soft performance.  

Usage 
It is mainly used in dielectric and mechanical protection, joints and terminals.

Specification
Property Unit Standard Test Method
Tensile Strength MPA ≥10.4(before aging) GB/T 1040
130ºC *168hrs
≥7.3(after aging)
Elongation % ≥300(before aging) GB/T 1040; GB/T7141
130ºC*168hrs
      ≥100(after aging)
Heat Shock - no sticking; no cracking JB 7829appendixD.(160ºC*4hrs)
Cold Blend - no cracking -30ºC*4hrs
Breakdown Strength KV/mm ≥25 GB/T 1408.1
Volume Resistivity Ω. cm ≥1×1014 GB/T 1410
Longitudinal Change % ≥50  
Off-center % ≤30 UL 224
Flame Retardant - ≥30 GD/T 2406
Water Absorption % ≤0.5 ISO 62-1980
Dielectric Withstand KV/mm ≥30kV.1min GB/T 1408.1
Shore Hardness(Shore A)   ≤90 GB 2401
*This data is suitable for 10kv bus bar protection tube. When managing this test, the user must make the tube recovery evenly and make sure the max thickness>2mm, and bus-bar tubes are longer than 1200mm.**35kV bus bar off center proportion≤50%.
 
Dimension
1KV Bus Bar Protection Heat Shrinkable Tube
Specification Bus Bar Width(mm) As Supplied(mm) After Recovery(mm) Standard Package
    ID Wall Thickness ID   Wall Thickness        (m/roll)
1KV WMPG 30 30 31.5±1.0 0.50±0.15 ≤15.0 1.00±0.15 50
1KV WMPG 35 35 36.5±1.0 0.50±0.15 ≤17.5 1.00±0.15 50
1KV WMPG 40 40 41.5±1.0 0.55±0.15 ≤20.0 1.00±0.15 50
1KV WMPG 45 45 46.5±1.0 0.55±0.15 ≤22.5 1.00±0.15 25
1KV WMPG 50 50 ≥50 0.55±0.15 ≤25.0 1.10±0.15 25
1KV WMPG 60 60 ≥60 0.60±0.15 ≤30.0 1.20±0.15 25
1KV WMPG 70 70 ≥70 0.65±0.15 ≤35.0 1.30±0.20 25
1KV WMPG 75* 75 ≥75 0.65±0.15 ≤38.0 1.30±0.20 25
1KV WMPG 80 80/100 ≥80 0.65±0.15 ≤40.0 1.30±0.20 25
1KV WMPG 85* 80/100 ≥85 0.65±0.15 ≤43.0 1.30±0.20 25
1KV WMPG 90 100 ≥90 0.65±0.15 ≤45.0 1.30±0.20 25
1KV WMPG 100 100/120 ≥100 0.65±0.20 ≤50.0 1.30±0.20 25
1KV WMPG 120 150 ≥120 0.65±0.20 ≤60.0 1.30±0.20 25
1KV WMPG 150 180 ≥150 0.65±0.20 ≤70.0 1.30±0.20 25
1KV WMPG 180 MAX ≥180 0.65±0.30 ≤90.0 1.30±0.30 25
1KV WMPG 210* MAX ≥210 0.65±0.30 ≤105.0 1.30±0.30 25
1KV WMPG 230* MAX ≥230 0.65±0.30 ≤115.0 1.30±0.30 25
1KV WMPG 250* MAX ≥250 0.65±0.30 ≤125.0 1.30±0.30 25

10KV Bus Bar Protection Heat Shrinkable Tube
Specification Bus Bar Width(mm) As Supplied(mm) After Recovery(mm) Standard Package
ID Wall Thickness ID Wall Thickness (m/roll)
10KV WMPG 15/6 15/12 ≥15 1.0±0.30 ≤6.0 2.5±0.20 25
10KV WMPG 20/8 20/15 ≥20 1.0±0.30 ≤8.0 2.5±0.20 25
10KV WMPG 25/10 25/18 ≥25 1.0±0.30 ≤10.0 2.5±0.20 25
10KV WMPG 30/12 30/20 ≥30 1.0±0.30 ≤12.0 2.5±0.20 25
10KV WMPG 40/16 40/30 ≥40 1.2±0.30 ≤16.0 2.8±0.30 25
10KV WMPG 50/20 50/35 ≥50 1.2±0.30 ≤20.0 2.8±0.30 25
10KV WMPG 60/24 60/45 ≥60 1.2±0.30 ≤24.0 2.8±0.30 25
10KV WMPG 65/26* 65/45 ≥65 1.2±0.30 ≤26.0 2.8±0.30 25
10KV WMPG 70/28 70/50 ≥70 1.2±0.30 ≤28.0 2.8±0.30 25
10KV WMPG 75/30* 75/50 ≥75 1.2±0.30 ≤30.0 2.8±0.30 25
10KV WMPG 80/32 80/55 ≥80 1.2±0.30 ≤32.0 2.8±0.30 25
10KV WMPG 85/34* 80/65 ≥85 1.2±0.30 ≤34.0 2.8±0.30 25
10KV WMPG 100/40 100/75 ≥100 1.2±0.30 ≤40.0 2.8±0.30 25
10KV WMPG 120/48 120/85 ≥120 1.2±0.30 ≤48.0 2.8±0.30 25
10KV WMPG 150/60 150/105 ≥150 1.2±0.30 ≤60.0 2.8±0.30 25
10KV WMPG 180/72 180/120 ≥180 1.2±0.30 ≤72.0 2.8±0.30 25
10KV WMPG 210/84* 210/140 ≥210 1.2±0.40 ≤84.0 2.8±0.30 25
10KV WMPG 230/92* 230/150 ≥230 1.2±0.40 ≤92.0 2.8±0.30 25
10KV WMPG 250/100* 250/160 ≥250 1.2±0.40 ≤100.0 2.8±0.30 2
 
35 KV Bus Bar Protection Heat Shrinkable Tube
Specification Bus Bar Width (mm) As Supplied(mm) After Recovery(mm) Standard Package
ID Wall Thickness ID Wall Thickness (m/roll)
35KV WMPG 30/15 30 ≥30 2.0±0.60 ≤15.0 4.0±0.30 15
35KV WMPG 35/18 30/40 ≥35 2.0±0.60 ≤17.5 4.0±0.30 15
35KV WMPG 40/20 40 ≥40 2.0±0.60 ≤20.0 4.0±0.30 15
35KV WMPG 50/25 50 ≥50 2.0±0.60 ≤25.0 4.0±0.30 15
35KV WMPG 60/30 60 ≥60 2.0±0.60 ≤30.0 4.0±0.30 15
35KV WMPG 65/33* 60/70 ≥65 2.0±0.60 ≤32.5 4.0±0.30 15
35KV WMPG 70/35 70 ≥70 2.0±0.60 ≤35.0 4.0±0.30 15
35KV WMPG 75/38* 70/80 ≥75 2.0±0.60 ≤37.5 4.0±0.30 15
35KV WMPG 80/40 80/100 ≥80 2.0±0.60 ≤40.0 4.0±0.30 15
35KV WMPG 100/50 100/120 ≥100 2.0±0.60 ≤50.0 4.0±0.30 15
35KV WMPG 120/60 150 ≥120 2.0±0.60 ≤60.0 4.0±0.30 15
35KV WMPG 150/75 180 ≥150 2.0±0.70 ≤75.0 4.0±0.30 15
35KV WMPG 180/90* MAX ≥180 2.0±0.70 ≤90.0 4.0±0.30 15
35KV WMPG 210/105* MAX ≥210 2.0±0.70 ≤105.0 4.0±0.30 15
35KV WMPG 230/115* MAX ≥230 2.0±0.70 ≤115.0 4.0±0.30 15
35KV WMPG 250/115* MAX ≥250 2.0±0.70 ≤125.0 4.0±0.30 15
Remarks: There is no storage if the item is marked *. It should be especially customized.

Color: Standard color is red, yellow, green.
High Voltage Protection Busbar Heat Shrink TubeHigh Voltage Protection Busbar Heat Shrink TubeHigh Voltage Protection Busbar Heat Shrink Tube

High Voltage Protection Busbar Heat Shrink TubeHigh Voltage Protection Busbar Heat Shrink TubeHigh Voltage Protection Busbar Heat Shrink Tube

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier