Customization: | Available |
---|---|
Application: | Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Motor, Mechanical Protection, Joints, Terminals |
Color: | Red, Yellow, Green, Other Color Available |
Still deciding? Get samples of US$ 0.00/Meter
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sunbow Electric Insulation High Voltage Bus Bar Protection Heat Shrinkable Tube
Model Number:SB-WMPG SERIES
Operation temperature:-55°C-125°C
STRUCTURE
High Voltage Bus Bar Protection Heat Shrinkable Tube adopts cross-linked and environment friendly polyethylene material. It restricts the hazardous substance in PBB, PBBD, PBBE and other heavy metal, and supplies high dielectric strength and voltage withstand performance. It prevents bus-bar from chemical corrosion effected by strong acid, alkali, salt etc.
USAGE:
Usage:Use in dielectric and mechanical protection, joints and terminals.
Application range: Electrical
CHARACTERISTICS:
Shrink ratio:2:1(1kV,35kV),2.5:1(10kV)
Shrink temperature:84°C~125°C
Operating temperature:-55°C~125°C
Environmental, Flexible, flammable, and soft
STANDARD
a. GB/T 1059-2007
b. Environment certificate:ROHS,
SPECIFICATION of Sunbow Electric Insulation High Voltage Bus Bar Protection Heat Shrinkable Tube
**35kV bus bar off center proportion≤50%*This data is suitable for 10kv bus bar protection tube. When managing this test, the user must make the tube recovery evenly and make sure the max thickness>2mm, and bus-bar tubes are longer than 1200mm.
DIMENSION
1KV Bus Bar Protection Heat Shrinkable Tube
Specification | Bus Bar Width(mm) | As Supplied(mm) | After Recovery(mm) | Standard Package | |
ID | ID | Wall Thickness | (m/roll) | ||
1KV WMPG 30/15 | 30 | 31.5±1.0 | ≤15.0 | 0.95±0.15 | 50 |
1KV WMPG 35/18 | 35 | 36.5±1.5 | ≤18.0 | 1.00±0.15 | 50 |
1KV WMPG 40/20 | 40 | 41.5±1.5 | ≤20.0 | 1.00±0.15 | 50 |
1KV WMPG 45/23 | 45 | 41.5±1.5 | ≤23.0 | 1.00±0.15 | 25 |
1KV WMPG 50/25 | 50 | 51.0±2.0 | ≤25.0 | 1.00±0.15 | 25 |
1KV WMPG 60/30 | 60 | 60.0±3.0 | ≤30.0 | 1.30±0.20 | 25 |
1KV WMPG 65/33* | 65 | 65.0±3.0 | ≤33.0 | 1.30±0.20 | 25 |
1KV WMPG 70/35 | 70 | 70.0±3.0 | ≤35.0 | 1.30±0.20 | 25 |
1KV WMPG 75/38* | 75 | 75.0±3.0 | ≤38.0 | 1.30±0.20 | 25 |
1KV WMPG 80/40 | 80/100 | 80.0±3.0 | ≤40.0 | 1.46±0.20 | 25 |
1KV WMPG 85/43* | 80/100 | 85.0±3.0 | ≤43.0 | 1.46±0.20 | 25 |
1KV WMPG 90/45 | 100 | 90.0±4.0 | ≤45.0 | 1.46±0.20 | 25 |
1KV WMPG 100/50 | 100/120 | 100.0±4.0 | ≤50.0 | 1.46±0.20 | 25 |
1KV WMPG 120/60 | 150 | 120.0±4.0 | ≤60.0 | 1.46±0.20 | 25 |
1KV WMPG 150/75 | 180 | 150.0±4.0 | ≤75.0 | 1.46±0.20 | 25 |
1KV WMPG 180/90 | MAX | 180.0±4.0 | ≤90.0 | 1.46±0.20 | 25 |
1KV WMPG 210/105* | MAX | 210.0±4.0 | ≤105.0 | 1.46±0.20 | 25 |
1KV WMPG 230/115* | MAX | 230.0±4.0 | ≤115.0 | 1.46±0.20 | 25 |
1KV WMPG 250/125* | MAX | 250.0±5.0 | ≤125.0 | 1.46±0.20 | 25 |
10KV Bus bar Protection Heat shrinkable Tube
Specification | Bus Bar Width(mm) | As Supplied(mm) | After Recovery(mm) | Standard Package | |
ID | ID | Wall Thickness | (m/roll) | ||
10KV WMPG 15/8 | 15/12 | ≥15 | ≤8.0 | 2.1±0.30 | 25 |
10KV WMPG 20/10 | 20/15 | ≥20 | ≤10.0 | 2.1±0.30 | 25 |
10KV WMPG 25/12 | 25/18 | ≥25 | ≤12.5 | 2.1±0.30 | 25 |
10KV WMPG 30/15 | 30/20 | ≥30 | ≤15.0 | 2.1±0.30 | 25 |
10KV WMPG 40/20 | 40/30 | ≥40 | ≤20.0 | 2.3±0.30 | 25 |
10KV WMPG 50/25 | 50/35 | ≥50 | ≤25.0 | 2.3±0.30 | 25 |
10KV WMPG 60/30 | 60/45 | ≥60 | ≤30.0 | 2.3±0.30 | 25 |
10KV WMPG 65/33* | 65/45 | ≥65 | ≤33.0 | 2.3±0.30 | 25 |
10KV WMPG 70/35 | 70/50 | ≥70 | ≤35.0 | 2.3±0.30 | 25 |
10KV WMPG 75/38* | 75/50 | ≥75 | ≤38.0 | 2.3±0.30 | 25 |
10KV WMPG 80/40 | 80/55 | ≥80 | ≤40.0 | 2.3±0.30 | 25 |
10KV WMPG 85/43* | 80/65 | ≥85 | ≤43.0 | 2.4±0.30 | 25 |
10KV WMPG 100/50 | 100/75 | ≥100 | ≤50.0 | 2.4±0.30 | 25 |
10KV WMPG 120/60 | 120/85 | ≥120 | ≤60.0 | 2.4±0.30 | 25 |
10KV WMPG 150/75 | 150/105 | ≥150 | ≤75.0 | 2.4±0.30 | 25 |
10KV WMPG 180/90 | 180/120 | ≥180 | ≤90.0 | 2.4±0.30 | 25 |
10KV WMPG 210/105* | 210/140 | ≥210 | ≤105.0 | 2.4±0.30 | 20 |
10KV WMPG 230/115* | 230/150 | ≥230 | ≤115.0 | 2.4±0.30 | 20 |
10KV WMPG 250/180* | 250/160 | ≥250 | ≤125.0 | 2.4±0.30 | 20 |
10KV WMPG 300/150* | 300/210 | ≥300 | ≤150 | 2.4±0.30 | 15 |
20KV Bus Bar Protection Heat shrinkable Tube
Specification | Bus Bar Width (mm) | As Supplied(mm) | After Recovery(mm) | Standard Package | |
ID | ID | Wall Thickness | (m/roll) | ||
20kV WMPG 15/8 | 15/12 | ≥15 | ≤8.0 | 2.5±0.20 | 20 |
20kV WMPG 20/10 | 20/15 | ≥20 | ≤10.0 | 2.5±0.20 | 20 |
20KV WMPG 25/13 | 25/18 | ≥25 | ≤13.0 | 2.5±0.20 | 20 |
20KV WMPG 30/15 | 32/20 | ≥30 | ≤15.0 | 2.5±0.20 | 20 |
20KV WMPG 40/20 | 40/30 | ≥40 | ≤20.0 | 2.8±0.30 | 20 |
20KV WMPG 50/25 | 50/35 | ≥50 | ≤25.0 | 2.8±0.30 | 25 |
20KV WMPG 60/30 | 60/45 | ≥60 | ≤30.0 | 2.8±0.30 | 25 |
20KV WMPG 65/33* | 65/45 | ≥65 | ≤33.0 | 2.8±0.30 | 25 |
20KV WMPG 70/35 | 70/50 | ≥70 | ≤35.0 | 2.8±0.30 | 25 |
20KV WMPG 75/38* | 75/50 | ≥75 | ≤38.0 | 2.8±0.30 | 25 |
20KV WMPG 80/40 | 80/55 | ≥80 | ≤40.0 | 2.8±0.30 | 25 |
20KV WMPG 85/43* | 80/45 | ≥85 | ≤43.0 | 2.8±0.30 | 25 |
20KV WMPG 100/50 | 100/120 | ≥100 | ≤50.0 | 2.8±0.30 | 25 |
20KV WMPG 120/60 | 150 | ≥120 | ≤60.0 | 2.8±0.30 | 25 |
20KV WMPG 150/75 | 180 | ≥150 | ≤75.0 | 2.8±0.30 | 25 |
20KV WMPG 180/90* | MAX | ≥180 | ≤90.0 | 2.8±0.30 | 25 |
20KV WMPG 210/105* | MAX | ≥210 | ≤105.0 | 2.8±0.30 | 20 |
20KV WMPG 230/115* | MAX | ≥230 | ≤115.0 | 2.8±0.30 | 20 |
35KV Bus Bar Protection Heat shrinkable Tube
Specification | Bus Bar Width (mm) | As Supplied(mm) | After Recovery(mm) | Standard Package | |
ID | ID | Wall Thickness | (m/roll) | ||
35kV WMPG 15/8 | 15/12 | ≥15 | ≤8.0 | 4.0±0.30 | 15 |
35kV WMPG 20/10 | 20/15 | ≥20 | ≤10.0 | 4.0±0.30 | 15 |
35KV WMPG 30/15 | 30 | ≥30 | ≤15.0 | 4.0±0.30 | 15 |
35KV WMPG 35/18 | 30/40 | ≥35 | ≤18.0 | 4.0±0.30 | 15 |
35KV WMPG 40/20 | 40 | ≥40 | ≤20.0 | 4.0±0.30 | 15 |
35KV WMPG 50/25 | 50 | ≥50 | ≤25.0 | 4.0±0.30 | 15 |
35KV WMPG 60/30 | 60 | ≥60 | ≤30.0 | 4.0±0.30 | 15 |
35KV WMPG 65/33* | 60/70 | ≥65 | ≤32.5 | 4.0±0.30 | 15 |
35KV WMPG 70/35 | 70 | ≥70 | ≤35.0 | 4.0±0.30 | 15 |
35KV WMPG 75/38* | 70/80 | ≥75 | ≤38.5 | 4.0±0.30 | 15 |
35KV WMPG 80/40 | 80/100 | ≥80 | ≤40.0 | 4.0±0.30 | 15 |
35KV WMPG 100/50 | 100/120 | ≥100 | ≤50.0 | 4.0±0.30 | 15 |
35KV WMPG 120/60 | 150 | ≥120 | ≤60.0 | 4.0±0.30 | 15 |
35KV WMPG 150/75 | 180 | ≥150 | ≤75.0 | 4.0±0.30 | 15 |
35KV WMPG 180/90* | MAX | ≥180 | ≤90.0 | 4.0±0.30 | 15 |
35KV WMPG 210/105* | MAX | ≥210 | ≤105.0 | 4.0±0.30 | 15 |
35KV WMPG 230/115* | MAX | ≥230 | ≤115.0 | 4.0±0.30 | 15 |
35KV WMPG 250/125* | MAX | ≥250 | ≤125.0 | 4.0±0.30 | 15 |
35KV WMPG 300/150* | MAX | ≥300 | ≤150.0 | 4.0±0.30 | 15 |
ABOUT SUNBOW
Shenzhen Sunbow insulation Materials MFG Co., Ltd, established in 2003,mainly engaged in the research& development ,manufacture and sales of various insulation materials.
Our products are silicone fiberglass sleeving, PVC tubing, silicone Tubing, Heat shrinkable Tube, PET expandable sleeve, corrugated pipe.
We are a IATF16949 and ISO 9001 manufactuer of insulation materials. We supply to many big brands as as ABB, WHIRLPOOL, TOSHIBA, SIEMENS, TOYATA, VOLVO and son on.
WHY SUNBOW
1. We are the china Top leading manufacture of heat shrink tube.
2. Good after sales service. we can promise one year quality gurantee.
3. Price is competitive.
4.We are IATF16949 and ISO 9001 manufactuer.
5. Our products are complied with UL, ROHS, REACH.
6. We are in Shenzhen, which is a trade and manufacturing city.
HOW TO CONTACT
Sunbow Electric Insulation High Voltage Bus Bar Protection Heat Shrinkable Tube